Kev_1's latest conversations

Kev_1 Conductor
3 weeks ago

Re: solar panel output being restricted

Finally found out the issue (myself, no “experts”). Inverter fan stopped working and the inverter each day overheated so the power output was “derated”. Error code 517, Fronius Primo inverter.there is a replacement inverter coming soon, under warranty. In the meantime, I’ve got a pedestal fan blowing against the inverter and the output is pretty much back up to where it should be.
Solved 16 Replies 0 Likes
Kev_1 Conductor
22-01-2024

Re: solar panel output being restricted

Been in touch and getting back in touch as they’ve had the data for nearly a week now.A quick look will tell them something is wrong and they need to send someone out to look at it at the very least
16 Replies 1 Like
Kev_1 Conductor
22-01-2024

Re: solar panel output being restricted

I’m in Mile End in Adelaide and the stats you have for your property is similar to what my system was producing prior to the battery fit.I’ve been in contact with AGL and provided them with a range of daily and monthly data from pre and post battery fitment and am just waiting for them to get back to me (will be emailing them today as they have had a few days now) to arrange someone to check the system.Currently, each day the system is reaching 2.8 kw at around 9.00 - 9.30 irrespective of cloud ...
16 Replies 0 Likes
Kev_1 Conductor
16-01-2024
16 Replies 0 Likes